{"id":2493,"date":"2026-11-03T16:06:35","date_gmt":"2026-11-03T16:06:35","guid":{"rendered":"https:\/\/www.kingbaseglobal.com\/blog\/tech-blog\/real-time-data-sync-cdc-setup-verification-rollback\/"},"modified":"2026-11-03T16:06:35","modified_gmt":"2026-11-03T16:06:35","slug":"real-time-data-sync-cdc-setup-verification-rollback","status":"publish","type":"post","link":"https:\/\/www.kingbaseglobal.com\/blog\/tech-blog\/real-time-data-sync-cdc-setup-verification-rollback\/","title":{"rendered":"Real-Time Data Sync_ CDC Setup, Verification &amp; Rollback"},"content":{"rendered":"<p><img decoding=\"async\" src=\"https:\/\/kingbase-bbs.oss-cn-beijing.aliyuncs.com\/qywx\/blogImage\/81c27509-d7bd-43e6-a36a-7dd480159600.webp\" alt=\"Precision tools arranged on linen representing technical configuration steps for data synchronization\" \/><\/p>\n<h2>Real-Time Data Sync with Apache SeaTunnel: CDC Setup, Verification &amp; Rollback<\/h2>\n<p>Choosing the right synchronization mode depends on the workload characteristics. Transactional systems generate high-frequency writes. Analytics dashboards require near-instant visibility into these changes.<\/p>\n<p>Apache SeaTunnel CDC jobs operate in STREAMING mode. They read the database transaction log (binlog). They capture change events including the operation type, before and after images, and metadata. This method provides real-time incremental synchronization. It can optionally precede the stream with a full snapshot of existing data.<\/p>\n<p>Apache SeaTunnel JDBC batch processing operates in BATCH mode. It executes a SQL query. It captures static data snapshots via the result set. This method provides one-time full or incremental batch synchronization. It does not capture subsequent changes until the next scheduled run.<\/p>\n<p>The table below compares the core differences based on Apache SeaTunnel documentation.<\/p>\n<table>\n<thead>\n<tr>\n<th style=\"text-align:left\">Feature<\/th>\n<th style=\"text-align:left\">CDC (Streaming)<\/th>\n<th style=\"text-align:left\">JDBC Batch Processing<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"text-align:left\">Job Mode<\/td>\n<td style=\"text-align:left\">STREAMING<\/td>\n<td style=\"text-align:left\">BATCH<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align:left\">Data Source<\/td>\n<td style=\"text-align:left\">Database Binlog<\/td>\n<td style=\"text-align:left\">SQL Query Result Set<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align:left\">Data Content<\/td>\n<td style=\"text-align:left\">Change Event Stream (operation type, before\/after images, metadata)<\/td>\n<td style=\"text-align:left\">Static Data Snapshot<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align:left\">Core Configuration<\/td>\n<td style=\"text-align:left\"><code>table-names<\/code><\/td>\n<td style=\"text-align:left\"><code>query<\/code> or <code>table + sql<\/code><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align:left\">Synchronization Type<\/td>\n<td style=\"text-align:left\">Real-time incremental (optionally full snapshot first)<\/td>\n<td style=\"text-align:left\">One-time full or incremental batch<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Log-based replication minimizes source database load compared to polling in the context of Apache SeaTunnel. Polling requires repeated queries that compete with transactional workloads. Log-based replication reads the append-only log. It does not lock tables or consume significant CPU cycles on the source. This isolation is critical for maintaining source performance during real-time data synchronization.<\/p>\n<h2>Prerequisites: Driver Versions and Environment Constraints<\/h2>\n<p>Stable connectivity requires strict adherence to version constraints. Incompatible drivers cause connection failures or silent data corruption.<\/p>\n<p>For MySQL CDC in Apache SeaTunnel version 2.3.3, the JDBC driver version is a hard constraint. You must use MySQL JDBC Driver 8.0.33 or later. Earlier versions lack the necessary protocol support for modern binlog formats. They may also introduce latency in packet parsing.<\/p>\n<p>Prepare the environment before starting the configuration.<\/p>\n<ol>\n<li>Verify the MySQL JDBC Driver version. It must be 8.0.33 or later.<\/li>\n<li>Ensure the source database has binary logging enabled. Check the <code>log_bin<\/code> setting.<\/li>\n<li>Confirm the binary log format is set to <code>ROW<\/code>. Statement-based logging does not capture before\/after images reliably.<\/li>\n<li>Create a dedicated user for CDC with <code>REPLICATION SLAVE<\/code> and <code>REPLICATION CLIENT<\/code> privileges.<\/li>\n<li>Verify network connectivity between the CDC connector and the source database.<\/li>\n<\/ol>\n<p>Missing these prerequisites often leads to immediate job failure. The connector cannot read the binlog position without the correct driver and privileges.<\/p>\n<h2>Configuration: Defining Sources for Real-Time vs. Batch Jobs<\/h2>\n<p>Configuration syntax differs significantly between streaming and batch modes. Using the wrong parameter structure causes parsing errors.<\/p>\n<p>CDC configuration uses <code>table-names<\/code> to specify sources. This parameter accepts a list of fully qualified table names. The connector monitors these specific tables for changes.<\/p>\n<p>JDBC configuration uses <code>query<\/code> or <code>table + sql<\/code> to specify sources. This allows arbitrary SQL logic for batch extraction. It does not support real-time monitoring of individual table changes.<\/p>\n<p>The following example demonstrates the correct syntax for a CDC source definition in Apache SeaTunnel. The <code>plugin<\/code> field identifies the connector type. <code>MySQL-CDC<\/code> is the specific plugin name for log-based replication.<\/p>\n<pre><code class=\"language-json\">{\n  &quot;source&quot;: {\n    &quot;plugin&quot;: &quot;MySQL-CDC&quot;,\n    &quot;table-names&quot;: [\n      &quot;db1.orders&quot;,\n      &quot;db1.customers&quot;\n    ],\n    &quot;connection&quot;: {\n      &quot;jdbc-url&quot;: &quot;jdbc:mysql:\/\/source-host:3306\/db1&quot;,\n      &quot;username&quot;: &quot;cdc_user&quot;,\n      &quot;password&quot;: &quot;password&quot;\n    }\n  }\n}\n<\/code><\/pre>\n<p>This configuration activates the streaming mode. The connector connects to the binlog. It begins reading events for the specified tables.<\/p>\n<p>In contrast, a JDBC batch source would look like this:<\/p>\n<pre><code class=\"language-json\">{\n  &quot;source&quot;: {\n    &quot;plugin&quot;: &quot;Jdbc&quot;,\n    &quot;query&quot;: &quot;SELECT * FROM db1.orders WHERE update_time &gt; '${last_sync_time}'&quot;,\n    &quot;connection&quot;: {\n      &quot;jdbc-url&quot;: &quot;jdbc:mysql:\/\/source-host:3306\/db1&quot;,\n      &quot;username&quot;: &quot;batch_user&quot;,\n      &quot;password&quot;: &quot;password&quot;\n    }\n  }\n}\n<\/code><\/pre>\n<p>This configuration executes a static query. It retrieves a snapshot. It does not establish a persistent stream.<\/p>\n<h2>Implementation: Setting Up Multi-Table CDC Monitoring<\/h2>\n<p>A single Apache SeaTunnel CDC job can monitor multiple tables simultaneously. It synchronizes them in real time. This reduces operational overhead compared to managing individual jobs per table.<\/p>\n<p>The implementation follows a phased approach.<\/p>\n<ol>\n<li>Define the source connector using the <code>MySQL-CDC<\/code> plugin.<\/li>\n<li>List all target tables in the <code>table-names<\/code> array.<\/li>\n<li>Configure the sink connector. Ensure it supports upserts or inserts to handle the change events.<\/li>\n<li>Set the job mode to <code>STREAMING<\/code>. This is the default for CDC plugins but must be explicit in some frameworks.<\/li>\n<li>Start the job and monitor the initial snapshot phase.<\/li>\n<\/ol>\n<p>The job enters the snapshot phase first. It reads the current state of all listed tables. It writes these records to the sink. Once the snapshot completes, the job transitions to the streaming phase. It begins consuming binlog events.<\/p>\n<p>Monitor the job status closely during this transition. The job should report no lag once it catches up to the current binlog position. If the job stalls, check the sink connectivity. A blocked sink prevents the connector from acknowledging events. This causes the local binlog buffer to fill up.<\/p>\n<h2>Handling Schema Evolution and Conflict Resolution<\/h2>\n<p>Schema changes break pipelines if not handled correctly. DDL changes on the source table alter the expected event structure.<\/p>\n<p>Log-based CDC does not automatically handle DDL changes. The connector expects a consistent schema for the monitored tables. A <code>ALTER TABLE<\/code> statement on the source can cause the connector to throw an error. It cannot parse the new column structure.<\/p>\n<p>Implement a schema evolution strategy.<\/p>\n<ol>\n<li>Freeze schema changes during the initial sync.<\/li>\n<li>If a schema change is required, pause the CDC job.<\/li>\n<li>Apply the DDL change to the source.<\/li>\n<li>Apply the same DDL change to the target system.<\/li>\n<li>Restart the CDC job. It will start from the current binlog position.<\/li>\n<\/ol>\n<p>Conflict resolution is another critical constraint. Concurrent updates from multiple sources can cause duplicate records. Use idempotency in the sink layer. The sink should use primary keys to upsert records. This ensures that duplicate events do not create duplicate rows.<\/p>\n<h2>Verification: Ensuring Data Consistency and Integrity<\/h2>\n<p>Verification confirms that the stream matches the source state. Static snapshots from JDBC batch jobs are easy to verify with row counts. CDC verification requires tracking the event stream.<\/p>\n<p>CDC captures before and after images. Use this metadata to validate data integrity.<\/p>\n<ol>\n<li>Compare the total row count in the source table with the target table.<\/li>\n<li>Check the checksum of a sample of rows. Ensure the <code>after<\/code> image in the CDC event matches the target record.<\/li>\n<li>Monitor the CDC lag metric. It should be near zero during steady state.<\/li>\n<li>Verify that all operation types (INSERT, UPDATE, DELETE) are present in the sink.<\/li>\n<\/ol>\n<p>If the lag metric spikes, the sink is likely slow. If the lag metric drops to zero but the data is stale, the connector may have lost its binlog position. This requires a rollback and restart from a known good snapshot.<\/p>\n<h2>Troubleshooting: Binlog Retention and Driver Incompatibilities<\/h2>\n<p>Common failure modes involve binlog retention and driver issues. These are the primary content risks for CDC implementations.<\/p>\n<p>Binlog retention issues occur when the source database purges binary logs. The CDC connector requests a position that no longer exists. The job fails with a &quot;Binlog Position Not Found&quot; error.<\/p>\n<p>To resolve this:<\/p>\n<ol>\n<li>Check the source database binlog retention period.<\/li>\n<li>Increase the retention period if it is too short.<\/li>\n<li>Restart the CDC job by setting the <code>startup.mode<\/code> parameter to <code>initial<\/code>. This forces a new full snapshot.<\/li>\n<li>Accept the temporary data duplication during the snapshot phase.<\/li>\n<\/ol>\n<p>Driver incompatibilities cause connection drops. The MySQL JDBC Driver 8.0.33 or later is required. Earlier versions may fail to parse the new authentication protocol. They may also fail to read the new binlog event format.<\/p>\n<p>Check the connector logs for <code>ClassNotFoundException<\/code> or <code>SQLException<\/code>. Update the driver JAR file in the connector environment. Restart the job.<\/p>\n<h2>Rollback Strategy: Restoring Consistency After Sync Failures<\/h2>\n<p>Rollback procedures are necessary when the target system becomes inconsistent. This can happen due to sink corruption or severe lag.<\/p>\n<p><strong>Warning:<\/strong> The <code>Truncate<\/code> command is a destructive action. It permanently deletes all data in the target tables. This should only be used as a last resort when data corruption is confirmed. Always ensure you have a recent backup or a valid snapshot configuration before proceeding.<\/p>\n<ol>\n<li>Stop the CDC job immediately.<\/li>\n<li>Identify the last known good binlog position.<\/li>\n<li>Truncate the target tables. Remove the corrupted data.<\/li>\n<li>Re-run the full snapshot. Configure the job to start from the beginning.<\/li>\n<li>Resume the streaming phase.<\/li>\n<\/ol>\n<p>This procedure ensures that the target system returns to a known good state. It avoids partial or duplicate data.<\/p>\n<p>The path to operational readiness depends on these verification and rollback steps. Engineers must validate the driver version, configure <code>table-names<\/code> correctly, and monitor the stream continuously. Real-time data synchronization is not a set-and-forget task. It requires active management of consistency and latency.<\/p>\n<h2>FAQ<\/h2>\n<h3>Should I use log-based replication or trigger-based CDC for my use case?<\/h3>\n<p>Log-based replication is generally superior for heterogeneous systems. It does not modify the source schema. Trigger-based CDC requires adding triggers to source tables. This increases source database load and complicates schema evolution.<\/p>\n<h3>What are the trade-offs between eventual and strong consistency in real-time analytics?<\/h3>\n<p>Real-time sync typically offers eventual consistency. The target system may lag behind the source by milliseconds. Strong consistency requires synchronous replication. This blocks source transactions until the target acknowledges the write. This increases source latency and reduces throughput.<\/p>\n<h3>How do I validate data integrity after a sync failure?<\/h3>\n<p>Compare row counts and checksums between the source and target. Verify that the CDC lag metric is near zero. Check for missing operation types in the sink logs.<\/p>\n<h3>What is the recommended rollback procedure if the target system becomes inconsistent?<\/h3>\n<p>Stop the job. Truncate the target tables only if data corruption is confirmed and backups exist. Restart the job with a full snapshot configuration. This ensures a clean state before resuming streaming.<\/p>\n<h3>How does the chosen sync method affect the performance of the source database?<\/h3>\n<p>Log-based CDC has minimal impact. It reads the append-only log. JDBC batch polling consumes CPU and I\/O. It competes with transactional queries. Choose CDC for high-frequency write workloads.<\/p>\n<hr \/>\n<p><strong>\ud83d\udca1 More Resources<\/strong><\/p>\n<p>If you would like to dive deeper into KingbaseES and its application practices across various industries, we have compiled the following official resources to help you get started quickly and develop and operate with efficiency:<\/p>\n<ul>\n<li><a href=\"https:\/\/bbs.kingbase.com.cn\/\">Kingbase Community<\/a>: A one-stop interactive platform for technical exchanges, Q&amp;A, and experience sharing\u2014join forces with fellow DBAs and developers.<\/li>\n<li><a href=\"https:\/\/www.kingbaseglobal.com\/Solution-Oracle.html\">Kingbase Solutions<\/a>: One-stop full-stack database migration and cloud-native solutions, supporting smooth migration of multi-source heterogeneous data, ensuring high availability, real-time integration, and sustained high performance.<\/li>\n<li><a href=\"https:\/\/www.kingbaseglobal.com\/Customers.html\">Kingbase Case Studies<\/a>: Real-world user scenarios and implementation outcomes, showcasing KingbaseES&#8217;s outstanding capabilities in high availability, high performance, and IT adaptation.<\/li>\n<li><a href=\"https:\/\/docs.kingbase.com.cn\/en\">Kingbase Documentation<\/a>: Authoritative and comprehensive product manuals and technical guides, covering the entire lifecycle from installation and deployment to development, programming, and operations management.<\/li>\n<li><a href=\"https:\/\/www.kingbaseglobal.com\/Download.html\">Free Download<\/a>: Get the latest installation packages, drivers, tools, and patches, supporting multiple platforms and domestic chip architectures.<\/li>\n<li><a href=\"https:\/\/www.kingbaseglobal.com\/blog\/\">Digital Construction Encyclopedia<\/a>: Covers digital strategy planning, data integration, metrics management, database visualization applications, and more to empower enterprise digital transformation.<\/li>\n<\/ul>\n<p><strong>Open Source Resources:<\/strong><\/p>\n<ul>\n<li><a href=\"https:\/\/github.com\/hgsandy\/Kingbase-docs\">GitHub &#8211; Kingbase-docs<\/a>: Kingbase documentation open-source repository\u2014Stars and contributions are welcome.<\/li>\n<li><a href=\"https:\/\/gitee.com\/hgsandy\/kingbase-docs\">Gitee &#8211; Kingbase-docs<\/a>: Domestic mirror repository for Kingbase documentation for faster access.<\/li>\n<\/ul>\n<p>Welcome to explore the resources above and begin your Kingbase journey!<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Real-Time Data Sync with Apache SeaTunnel: CDC Setup, Verification &amp; Rollback Choosing the right synchronization mode depends on the workload characteristics. Transactional systems generate high-frequency writes. Analytics dashboards require near-instant&#8230;<\/p>\n","protected":false},"author":434,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"meta_description":"","_kingbase_seo_description":"","_kingbase_seo_keywords":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-2493","post","type-post","status-publish","format-standard","hentry","category-uncategorized"],"_links":{"self":[{"href":"https:\/\/www.kingbaseglobal.com\/blog\/wp-json\/wp\/v2\/posts\/2493","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kingbaseglobal.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.kingbaseglobal.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.kingbaseglobal.com\/blog\/wp-json\/wp\/v2\/users\/434"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kingbaseglobal.com\/blog\/wp-json\/wp\/v2\/comments?post=2493"}],"version-history":[{"count":0,"href":"https:\/\/www.kingbaseglobal.com\/blog\/wp-json\/wp\/v2\/posts\/2493\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.kingbaseglobal.com\/blog\/wp-json\/wp\/v2\/media?parent=2493"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.kingbaseglobal.com\/blog\/wp-json\/wp\/v2\/categories?post=2493"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.kingbaseglobal.com\/blog\/wp-json\/wp\/v2\/tags?post=2493"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}